Effective length factor

Effective length factor

How is a frame assigned a sidesway-uninhibited condition, rather than sidesway-inhibited?

Extended Question: Further, should I use the effective length factors automatically calculated through SAP2000? K = 1.0 for all members under any configuration, which does not seem accurate. Should K factors be input manually?

Answer:

CSI Software implements a rigorous process to determine K factors. A full description is available in the CSI  Steel Frame Design Manual (Help > Documentation > Design > Steel Frame Design > Design Algorithms > Element Unsupported Lengths > Effective Length Factor).

A notable point mentioned in this section (pages 11-14) is that K-factor calculations are based on the assumption of uninhibited sidesway. For other cases, K factors should be specified by the user. Users should always, however, use engineering judgment to evaluate the accuracy of K factors calculated by computational tools. Any discrepancy between the unbraced properties modeled and the actual design intention may lead to inappropriate design.

Automatically-generated K factors may be overwritten for individual members using the Overwrite option under Stress Check Information, as shown in Figure 1:


Figure 1 - Frame-property overwrite

See Also

Related content

Unsupported member length
Unsupported member length
More like this
Frame FAQ
More like this
Frame properties in database tables
Frame properties in database tables
More like this
Design first steps
Design first steps
More like this
Panel zone and rigid offset
Panel zone and rigid offset
More like this