Tension-only elements in ETABS
Tension-only elements in ETABS
Tension-only elements can be modeled using all versions of ETABS. The process is as follows:
- Select the elements to be specified as tension-only.
- Specify the tension limit (usually a limit higher than expected maximum tension capacity) and a compression limit of zero (or negative) through Assign > Frame/Line > Tension/Compression Limits.
- Define and Run a nonlinear static or nonlinear time-history analysis. This is necessary since tension-only assignment is a nonlinear feature. See below on how to convert any load case or combination to nonlinear.
Any load case or combination may be converted to a nonlinear analysis as follows:
- Select the case(s) through Define > Convert Combos to Nonlinear Cases
- Add the nonlinear case(s) to a user-defined combination with a scale factor of 1.0.
- For design, you can select the created nonlinear combination as design load combinations.
- Perform design.
Please note that response-spectrum analysis only applies to linear systems. Further, response-spectrum loads cannot be converted to nonlinear cases.
See Also
- Tension and compression limits article
, multiple selections available,
Related content
Modeling techniques
Modeling techniques
Read with this
Tuned-mass damper
Tuned-mass damper
More like this
Acceleration load in arbitrary direction
Acceleration load in arbitrary direction
More like this
Damping
Damping
More like this
Optimized Modeling and Design of Steel Structures using ETABS - ARCHIVAL
Optimized Modeling and Design of Steel Structures using ETABS - ARCHIVAL
More like this
Two-span girder simply-supported for DL and continuous for LL
Two-span girder simply-supported for DL and continuous for LL
More like this