Influence-based moving-load analysis can be setup using the following procedure:

  • Define Vehicle through "Loads Tab > Vehicles > New"
  • Define vehicle class through "Loads Tab > Vehicle Classes > New". Note that default vehicle class is automatically added for each vehicle.
  • Define layout line via "Layout Tab > Layout Line > New"
  • Define lane via "Layout Tab > Lane > New"
  • Define a moving-load case via "Analysis Tab > Load Cases > New". Set the load-case type to Moving Load, then specify the vehicles and lanes assigned to this moving load, as shown in Figure 1:


Figure 1: Moving load case definition