Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.


 

Tension-only elements can be modeled using the nonlinear version all versions of ETABS. The process is as follows:

  1. Select the elements to be specified as tension-only.
  2. Specify the tension limit (usually a limit higher than expected maximum tension capacity) and a compression limit of zero (or negative) through Assign > Frame/Line > Tension/Compression Limits.
  3. Define and Run a nonlinear static or nonlinear time-history analysis. This is necessary since tension-only assignment is a nonlinear feature.

...

  1. . See below on how to convert any load case or combination to nonlinear.


Any load case or combination may be converted to a nonlinear analysis as follows:

  1. Select the case(s) through Define > Convert Combos to Nonlinear Cases.Run a static-linear analysis, then once complete, run a static-nonlinear analysis (only required in V9, in V13 linear and nonlinear cases will run at once)
  2. Add the nonlinear case(s) to a user-defined combination with a scale factor of 1.0.
  3. Apply the For design, you can select  the created nonlinear combination as design load combinations.
  4. Perform design.

 


When full nonlinear behavior must be considered, nonlinear time-history analysis should be run since Please note that  response-spectrum analysis only applies to linear systems. Further, response-spectrum loads cannot be converted to nonlinear cases.

...