Tension-only elements can be modeled using the nonlinear version all versions of ETABS. The process is as follows:
- Select the elements to be specified as tension-only.
- Specify the tension limit (usually a limit higher than expected maximum tension capacity) and a compression limit of zero (or negative) through Assign > Frame/Line > Tension/Compression Limits.
- Define and Run a nonlinear static or nonlinear time-history analysis. This is necessary since tension-only assignment is a nonlinear feature. See below on how to convert any load case or combination to nonlinear.
Any load case or combination may be converted to a nonlinear analysis as follows:
- Select the case(s) through Define > Convert Combos to Nonlinear Cases. Run a static-linear analysis, then once complete, run a static-nonlinear analysis (only required in V9, in V13 linear and nonlinear cases will run in same analysis).
- Add the nonlinear case(s) to a user-defined combination with a scale factor of 1.0.
- Apply the For design, you can select the created nonlinear combination as design load combinations.
- Perform design.
When full nonlinear behavior must be considered, nonlinear time-history analysis should be run since Please note that response-spectrum analysis only applies to linear systems. Further, response-spectrum loads cannot be converted to nonlinear cases.
...
- Tension and compression limits article