Info |
---|
This page is devoted to frequently asked questions (FAQ) related to buckling. |
On this page:
Table of Contents |
---|
Analysis
Why do my hand calculations not match linear-buckling results?
ANSWER: Structural objects should be meshed before running linear-buckling analysis such that the software may accurately capture the instability modes under the specified set of loading conditions.
Show if | ||
---|---|---|
| ||
Related Incidents:
|
What happens analytically when a member reaches buckling capacity during nonlinear buckling analysis?
...
ANSWER: The internal forces and reactions reported for buckling load cases correspond to the buckled configuration of the structure. For a vertical cantilever model, the structure buckles laterally, generating internal moments and shears without axial force.
Show if | ||
---|---|---|
| ||
Related Incidents:
|
Why am I getting a negative-stiffness error during P-Delta analysis?
ANSWER: Negative stiffness occurs during P-Delta analysis when structural objects buckle under second-order P-Delta effects. To avoid negative stiffness and buckling, object size should be increased, especially at columns and diagonals.
Show if | ||
---|---|---|
| ||
Related Incidents:
|