Time-history analysis may be initiated using the process which follows:
Create the model and assign support conditions to restrained joints.
Select Define > Functions > Time History to define a time-history function which characterizes load variation over time.
Assign load conditions to the model through Assign > Joint Loads or Frame Loads.
Define either a modal or direct-integration time-history load case through Define > Load Cases.
To customize load application, enter, on the Load Case Data form under Load Applied, the following fields:
Load Type. Select the Load Pattern option.
Load Name. Select the Load Pattern to be applied.
Function. Select the time function which characterizes load variation in time.
See Also
CSI Analysis Reference Manual (Linear Time-History Analysis, page 353) and (Nonlinear Time-History Analysis, page 403)
Multi-support excitation article
Metadata
Name: Time-history analysis first steps
Description: Overview of the procedure for time-history analysis.
Program: SAP2000
Program Version:
Model ID: na