templateTest Problem

Temperature load is applied to a fixed-fixed beam with variable insertion point locations, including centroid (default) and top-center. The tutorial below demonstrates application, and compares theoretical solution to results obtained from a SAP2000 model.

PDF
nameanalysis notes.pdf

Attachments

Metadata

  • Name: Temperature load vs. insertion point

  • Description: Given temperature loading applied to a fixed-fixed beam with variable insertion point (centroid and top-center), theoretical solution is compared to that from a SAP2000 model.

  • Program: SAP2000

  • Program Version: 14.2.3

  • Model ID: na

Show if
groupIds9648cebd-43c5-412d-be51-b164167ddea5
users
matchUsingany
  • Location: ondrej/test_problems/sap2000/insertion point and temperature loading for fixed beam