Comment: added code values and reorganized

 

ACI: As recommended in the ACI 435R95 report (section 4.3.3),CSI Software has reduced the SAFE uses a default modulus-of-rupture value from 7.5√f 'c to of 4√f 'c. This change has been documented as Incident # 19168 in the CSI Release Notes of SAFE Version 12.3.0, Release Date 2010-07-12.

Through manual overwrite by checking radio button of User Specified, users are welcome to comply with the previous 7.5√f 'c value, or apply another value based on engineering judgment or project requirements. This is done by selecting Define > Materials... > Modify/Show Material... as shown in Figure 1:

 

Image Removed

 

PSI

For British, Hong Kong, Indian and Singapore Standards: program default Default modulus of rupture for cracked deflection is limited to 1 MPa or 0.55 MPa in short term and in long term deflection calculations, respectively. Those limits can be overwritten based on your engineering judgment by entering any other value under User Specified.

For Australian and New Zealand codes: fr= 0.36√f 'c  MPa

For Canadian code: fr= 0.3√f 'c MPa

For Euro-code:

 

Through manual overwrite by checking radio button of User Specified, users can comply with any other value based on engineering judgment or project requirements. This is done by selecting Define > Materials... > Modify/Show Material... as shown in Figure 1:

 

Image Added

                                                                                                                                                                                                       Figure 1 - Overwrite modulus of rupture