The self-weight multiplier controls whether or not structural self-weight is included within a given load pattern. Typically, a self-weight multiplier of 1.0 is only assigned to the load pattern which represents the self-weight of the structure . Then with a multiplier of zero is assigned to all other load patterns, but the . The load case which includes the self-weight load pattern is included within each load combination to account for the self-weight of the structure only once.

To ensure that self-weight is accounted for only once, check the base reactions listed in the output tables of any load case or combination.

Show if
groupeditors

Related Incidents:

  • Incident 48096: How to Define Inertia Load