Comment: Migrated to Confluence 4.0

...

How is the response factor calculated?

Answer: ETABS and SAP2000 compute the Resposne Factor usign the calculate response factor (RF) using the following equation:RESP-FACTOR

  • RF = [2.31 – 0.41 log (100 (Case + Link damping, express in ratio))] / [2.31 – 0.41 log (100 (Function damping, express in ratio))]  [1]

...

  • ,[2]

References

  1. Newmark, Nathan M.; Hall, William J. Engineering monographs on earthquake criteria, structural design, and strong motion records. Berkeley, CA: Earthquake Engineering Research Institute

...

  1. , 1982. Print.

  2. Comartin, Craig D.; Niewiarowski, Richard W. ATC-40, Seismic Evaluation and Retrofit of Concrete Buildings, Volume I. Redwood City, CA: Applied Technology Council, 1996. Print.