Hinge properties may be defined through Define > Section Properties > Hinge Properties, then they may be assigned to a selected frame object through Assign > Frame > Hinges. Additional details on frame hinges are available in the CSI Analysis Reference Manual (Chapter VIII Frame Hinge Properties, page 131).
- A link may be assigned to a joint panel zone by first selecting the common joint at a beam-column connection, then by assigning the joint panel zone through Assign > Joint > Panel Zone. Any link property may be specified when modeling the panel zone.
- A link may also be created manually by drawing the beam and column objects such that their ends are slightly offset, not sharing a common joint. A link property should then be defined to represent the connection stiffness, and the offset joints should be connected using Draw > Draw 2 Joint Link.
Show if | ||
---|---|---|
| ||
Related Incidents:
Related Emails:
TO DO: This could be improved. If the connection is linear, one can use end releases with partial fixity stiffness. If nonlinear, then the frame hinge (1) or link element (3) could be used. |