Within SAP2000, CSiBridge, and ETABS, a link object may be used to manually input a known 12x12 stiffness matrix which represents the connection between two joints.

...

A one-joint link provides a 6x6 stiffness between a single joint j and the ground. This is the same is the same as using a two-joint link and fully restraining joint i. The stiffness for the one-joint link is thus given by [Kj j ]. This means that the same link property can be used for a one-joint link or a two-joint link that has its first joint fully restrained. The same consideration for the sign of the 5th row and 5th column applies due to V2 = -F2.