Does ETABS amplify the displacement and drift levels reported for auto-lateral and response-spectrum load cases by Cd / I, as specified by ASCE 7-05
...
Section 12.8.6
...
?
Answer: ETABS reports the elastic displacement which is computed under strength-level design earthquake forces. The displacement (or and drift ) levels reported by for auto-lateral load and response-spectrum load cases must be amplified by Cd / I.