Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

In this example we assign a 1" Z direction displacement to the selected anchor in the T2 thermal load pattern to account for thermal growth of attached equipment using Assign menu>Point loads>Ground displacement. Since the model was in feet units, typing 1" was automatically converted into feet units. 

        

Below right we zoom into a skewed direction anchor with pipe support local axes graphically displayed. Anchors, guides, line stops, and distributed supports (soil) have local axes which by default align with the piping local axes. Local 1 is the red arrow, which is the longitudinal direction of the pipe, green arrow is local 2 and blue arrow is local 3. CSiPlant enables users to assign imposed displacement loads using local or global axes.

Image RemovedImage Added


Imposed Displacements at soil distributed supports

...