Modal analysis may be used to troubleshoot the convergence failure of a staged-construction load case. If the model fails to converge in stage X of a staged-construction case named Staged, modal analysis may indicate the convergence problem through the following process:

...

  • Run modal analysis, then check for instabilities while reviewing results (modal shapes, periods, etc.). Instabilities are clearly indicated by animating mode shapes.

 

Info

NOTE: A variation of this process may be used to troubleshoot convergence problems which occur during time-history analysis. When a certain step fails to converge, run analysis until that step, then run modal analysis using stiffness at that step to check for instabilities.